Brand Name : Chengtiantai cable

Model Number : YJV

Certification : CE, CB

Place of Origin : Shenzhen City, Mainland China

MOQ : 500 m

Price : On Request

Payment Terms : L/C, T/T

Delivery Time : 15 working days after payments

Packaging Details : Steel wooden Drum

Rated Voltage : 0.6 / 1kV

Conductor : Bear Copper

No. Of Cores : 4 Cores

Insulation : XLPE compound

Armoured Type : Unarmoured

Sheath : PVC Compound

Contact Now

IEC 60502-1 Cables

600/1000V, XLPE Insulated Cables according to IEC 60502-1

Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

Construction

1. Conductors

------------------------------------------------------------------------------------------------------

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

------------------------------------------------------------------------------------------------------

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

------------------------------------------------------------------------------------------------------

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

------------------------------------------------------------------------------------------------------

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

------------------------------------------------------------------------------------------------------

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

------------------------------------------------------------------------------------------------------

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

Physical and Electrical Characteristics:

No.cores x
cross-sec.
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
4×4 0.7 1.8 13.0 283 38 50 4.61
4×6 0.7 1.8 14.2 376 49 62 3.08
4×10 0.7 1.8 16.7 567 67 84 1.83
4×16 0.7 1.8 19.1 829 88 109 1.15
4×25 0.9 1.8 23.2 1249 119 142 0.73
4×35 0.9 1.8 25.2 1689 146 170 0.52
4×50 1.0 1.9 25.5 2146 173 201 0.39
4×70 1.1 2.0 28.9 2944 218 245 0.27
4×95 1.1 2.1 32.5 3903 271 294 0.19
4×120 1.2 2.3 35.9 4967 315 333 0.15
4×150 1.4 2.4 40.2 6133 366 374 0.12
4×185 1.6 2.6 44.4 7600 422 421 0.10
4×240 1.7 2.8 49.4 9743 508 489 0.08
4×300 1.8 3.0 56.0 12271 592 555 0.06

INSTALLATION METHOD DETAILS

IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable
B1 – Electroduct in brickwork (Single-core) B1 – Electroduct in brickwork (multi-core) C – On the wall  C – On the ceiling
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable
C – Non-perforated tray F – Perforated tray (Single-core) F – Perforated tray (multi-core) F –Suspended (Single-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable
E – Suspended (multi-core) B2 – Construction space B2 – Construction space B1 – Electroduct (Single-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable
B2 – Electroduct (Multi-core) B2 – Closed raceway embedded in floor (multi-core) B2 – Closed raceway embedded in floor (multi-core) B1 – Ventilated raceway embedded in floor
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable
C – Embedded in the brickwork D – Buried in additional mechanical protection

Cable Drum Data

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

RECOMMENDED ORDERING PARAMETERS

CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

WARRANTY

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

INSTALLATION METHOD DETAILS

IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable B1 – Electroduct in brickwork (Single-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable B1 – Electroduct in brickwork (multi-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable C – On the wall
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable C – On the ceiling
<img class="src=" photo="" copperconductorcable="" editor="" 20170927191416_90776.png"=""> A1 – Thermally insolated wall (Single-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable A2 – Thermally insolated wall (multi-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable B1 – Apparent electroduct (Single-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable B2 – Apparent electroduct (multi-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable C – Non-perforated tray
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable F – Perforated tray (Single-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable F – Perforated tray (multi-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable F –Suspended (Single-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable F – Perforated tray (Single-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable F – Perforated tray (multi-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable F –Suspended (Single-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable E – Suspended (multi-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable B2 – Construction space
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable B2 – Construction space
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable B1 – Electroduct (Single-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable B2 – Electroduct (Multi-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable B2 – Construction space
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable B2 – Closed raceway embedded in floor (multi-core)
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable B1 – Ventilated raceway embedded in floor
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable C – Embedded in the brickwork
IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable D – Buried in additional mechanical protection

Product Tags:

xlpe copper cable

      

xlpe pvc cable

      

4 core IEC 60502-1 Cable

      
Quality IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable for sale

IEC 60502-1 Cables 4 core (Unarmoured) | Cu-Conductor / XLPE Insulated / PVC Sheathed Power Cable Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Chengtiantai Cable Industry Development Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)